How does a monoflange work?

Monoflanges combine the event as high as three valves in a particularly compact body, because of an accurate network of internal passages and valve chambers. But what really happens inside a monoflange valve, once installed?
In a chemical process a higher response speed is required for most control applications. One of many variables that affect the response time may be the volume and the distance between process and instruments. If the medium to be measured is gas, and the process will fluctuate strongly at times or if the control is critical, mounting the instrument near the process is the solution.
Vibrations may also be critical, for example, if impulse lines are linked to a vessel. The longer the hook-up, the wider may be the amplitude of the vibration causing possible failures of the nozzle. A monoflange includes one, several needle valves in the compact, flange-shaped body, allowing a significant decrease in volume, dimensions, weight and potential leakage points.
Monoflange may be the solution
With respect to the requirements of the plant it is installed in, the monoflange can incorporate one, two or three valves. In a monoflange with two valves (block & bleed), one valve (with a blue cap) isolates the procedure and the other (with a red cap) regulates the venting of the medium trapped inside the instrument. This is mostly found in applications that are relatively uncritical (e.g. low pressure) or in which a first shut-off valve is provided right before the monoflange.
The safest configuration, and the one we advise for aggressive media or critical operating conditions, is the three-valve monoflange or the so-called double block & bleed (DBB), which features two shut-off valves in series and something valve for venting.
pressure gauge are drilled internally with holes which connect the annular valve chambers.
The next picture illustrates the procedure within a DBB monoflange:
The flow enters the monoflange from the pipeline and stops below the initial shut-off valve [1];
When the first shut-off valve [1] opens, the flow proceeds towards the second shut-off valve [2] ; once the valve [2] is open, the instrument is thus linked to the process line;
Once the first shut-off valve [1] is closed, the medium trapped between valve and instrument can be discharged via the vent valve [3] through the vent outlet. The two shut-off valves [1, 2] come in an angled position, that allows the flow to pass through them.
The two shut-off valves allow a better isolation from the process: In case the initial shut-off valve does not isolate the medium properly, the second one will become a safety means against accidental leaks. Occasionally, customer specifications do not allow the medium to stay touch with the instrument when it is not measuring. That is why the medium shall be discharged using the vent line. In other cases ? due to the vent line ? instruments can be easily calibrated without dismounting them from the line.
Note
More info on our valves are available on the WIKA website or in the video What is a monoflange? When you have any questions, your contact will gladly help you.