Pressure sensor with I�C communication ? possibilities and boundary conditions

I�C was made to communicate over short distances between printed circuit boards and is a simple, 8-bit serial data bus. For the time being, it isn’t only PCB-mountable pressure sensors that utilize the I�C signal for data transfer, but additionally pressure sensors remote from customer electronics.
pressure gauge octa will often have the advantage of being less sensitive to contaminated or aggressive media and being able to measure directly at the procedure. In the case of sensors mounted directly on the circuit board, the sensor element is, in many cases, exposed right to the medium. With remote sensors, steel or ceramic generally serve as the wetted surface.
I�C circuit
The I�C bus, alongside the two supply lines, requires only two further lines:
SCL (serial clock line)
SDA (serial data line)
Additional possibilities through I�C
The I�C bus is a well-known standard in electronics, offering additional possibilities for communication with a pressure sensor than with an analogue signal:
In the data protocol, as well as the pressure value, a temperature value and diagnostic information (for instance an integrity test of the info transfer) can be transmitted via a status byte.
Several pressure sensors could be linked to a bus line as ?slaves? to the client electronics that functions as a ?master?.
On the client side, in contrast to using pressure sensors with analogue signals, the analogue-to-digital conversion of the pressure value for further signal processing is unnecessary because the pressure value is already present in digital form. This contributes to faster and easier signal processing.
เกจวัดแรงดัน for communication can be constructed with standard components readily available on the market.
Often, I�C signal pressure sensors are also optimised to take less energy, making them perfect for battery-powered applications. In the WIKA portfolio, for example, this applies to the MPR-1 pressure sensor module.
Boundary conditions with the use of I�C
Since I�C is not a fieldbus, long wire lengths are not recommended. The maximum wire length depends, at length, on the operating environment and the corresponding disturbing influences. I�C communication is best used in projects where in fact the pressure sensor or the pressure sensor module is built-into the customer product and thus protected against external influences. It should also be noted that with any digitally processed signal, the response time due to discrete-time sampling will undoubtedly be somewhat slower than for an analogue, continuous signal.
Note
Your contact person will undoubtedly be happy to assist you to with any more questions on digital interfaces.
Distributed Intelligence
Distributed Intelligence on the integration of pressure sensors into hydraulic systems
Fill below form and we will send you the whitepaper ?Distributed Intelligence?.
Name
Company
E-mail
Send
We?re committed to your privacy. We?ll use your details to get hold of you about our products. Contact us at socialmedia@wika.com to revoke your permission to utilize your information.

Scroll to Top