In many places from chemistry laboratories to industrial facilities, to be able to guarantee the protection of life and property in opposition to a possible fire hazard, extinguishing techniques are used along with detection and alarm methods. It can be extremely important that the extinguishing methods installed could be triggered by the fireplace extinguishing management panel, in order to get rid of a possible fire with early intervention.
In order to meet these needs, and with 35 years of sectoral data and experience, Mavili Elektronik presents:
Maxlogic Conventional Fire Extinguishing Control Panel operating based on the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which permits the remote performance of the symptoms and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing course of to be started manually and remotely; and
to guarantee that the extinguishing course of could be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these units are produced using surface-mount technology and are aimed toward making the automation of the extinguishing system and hearth and fuel detection system perfect.
Image copyright: Mavili
Mavili Elektronik develops its merchandise by always contemplating the wants of the installation. In instances that require the mixing of the extinguishing system with the intelligent addressable hearth detection system, it supplies solutions via the monitoring modules that even have a ‘supervised’ choice.
Supervised monitoring modules play an necessary function in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a attainable open or brief circuit within the wiring between the contact monitoring modules and the peripheral methods can cause disruption of the triggering, with doubtlessly crucial penalties. For this reason, when selecting monitoring modules, it should be taken under consideration that they’ve supervised features.
Image copyright: Mavili
Since Maxlogic clever addressable fire detection and alarm control panels are continually speaking with ‘supervise’ contact monitoring modules connected to cable loops and compliant with EN 54-17 and EN 54-18 standards, it makes it simpler to observe conditions similar to open circuits and short circuits that may happen within the system. Many tasks may be carried out within the fireplace extinguishing set up, such as the management and monitoring of all valves that can interrupt the flow of water, water flow alarm switches, pressure swap, and electric or diesel hearth pumps.
By adding เกจวัดแรงดัน10bar monitoring modules to 2 separate relay outputs situated above the Maxlogic Conventional Fire Extinguishing Control Panel, one of many modules can be utilized to manage errors and the opposite to control the fire state of affairs, monitoring and control of the extinguishing system by way of an clever addressable hearth detection and alarm system can be carried out effectively.
For extra information, go to www.mavili.com.tr/en
Share